Filter Results By:

Products

Applications

Manufacturers

Showing results: 61 - 75 of 123 items found.

  • Dual Channel HV Amplifier with Phase Inverter

    A800DI - FLC Electronics Inc

    This unit contains two independent A800 amplifiers that share common ground reference and power supply. Please see A800 page for technical details.It features also a low voltage phase inverter that inverts the signal applied to the input of channel 1. The resulting signal can then be connected to the input of channel 2 by means of a short BNC cable (supplied). As a result the two outputs operate in counter-phase.

  • Rad-Hard Analog ICs

    STMicroelectronics

    ST's wide range of rad-hard QML-V qualified analog ICs covers analog-to-digital converters (ADC) and digital-to-analog converters (DAC) for telemetry, instrumentation and imaging applications. Our portfolio also includes rad-hard op amps, high-speed differential amplifiers up to 1 GHz, shunt voltage references and comparators to ensure a complete solution for signal conditioning, referencing and data conversion.

  • Precision Resistor Network

    Analog Devices Inc.

    Analog Devices provides a portfolio of quad resistor networks with excellent matching specifications over the entire temperature range. All of our resistors can be accessed and biased independently, making them a convenient and versatile choice for any application that can benefit from matched resistors. Our resistor networks provide the precise ratiometric stability required in highly accurate difference amplifiers, voltage references, and bridge circuits.

  • Current Sensing

    Texas Instruments

    voltage-output, current-sensing amplifier family that integrates an internal shunt resistor to enable high-accuracy current measurements at common-mode voltages that can vary from 0 V to 36 V, independent of the supply voltage. The device is a bidirectional, low- or high-side current-shunt monitor that allows an external reference to be used to measure current flowing in both directions through the internal current-sensing resistor sensor. The integration of the precision current-sensing resistor provides calibration equivalent measurement accuracy with ultra-low temperature drift performance and ensures an optimized Kelvin layout for the sensing resistor is always obtained.

  • Software

    Junction Measurement and Analysis - Materials Development Corporation

    A comprehensive set of analyses for junction diode or Schottky barriers begins with C-V data gathering that adjusts the voltage step to the slope of the C-V characteristics. This assures an optimum set of C-Vdata whether the voltage range is small or large. Doping profile and resistivity profile are both available at the touch of a key. Plots of 1/C2 - V or Log(C) - Log (V+ phi) show doping uniformity and doping slope factor. Exclusive recalculation options allow adjustment of stray capacitance and area to facilitate calibration using a standard reference wafer of known doping or resistivity.

  • NI-6581, 100 MHz, 54 Single-Ended-Channel Digital I/O Adapter Module

    780565-01 - NI

    100 MHz, 54 Single-Ended-Channel Digital I/O Adapter Module for FlexRIO—The NI-6581 is a digital I/O adapter module that, when combined with a PXI FPGA Module for FlexRIO, creates a digital instrument for interfacing with 54 single-ended digital pins. You can use the NI-6581 to do real-time interfacing of standard protocols and implement customized protocols. The NI-6581 can operate sample digital waveforms at up to 100 MHz. It includes support for common transistor-to-transistor logic (TTL) voltage levels, or other voltage references can be sourced externally using a front panel connector.

  • Digital Tank Test Kit

    4109 - M. C. Miller Company

    The voltmeter included in the kit, the “Model DPM” voltmeter, is designed for ease of use by meter readers and corrosion technicians alike and the voltmeter comes with an integrated RE-5 reference electrode attached for “metallic structure-to-soil” potential difference readings. The kit also includes a special test lead that has a brass thumb screw on one end which allows the test lead to substitute for the RE-5 reference electrode. This substitution allows the voltmeter to take “structure-to-structure” potential difference readings. The voltmeter offers two ranges, ±2VDC and ±20VDC with a 20MΩ input impedance. Since the voltmeter is digital [in contrast to the meter in our analog tank test kit (Cat. # 4108)], both negative and positive voltages are displayed. `

  • Oscilloscope App

    ONYX Apps

    Oscilloscope for iOS is great for analyzing audio range signals, or learning oscilloscope measurement basics. The interface includes many standard oscilloscope controls, such as: triggering, time and voltage per division, signal measurement cursors, and more. The app incorporates a signal (function) generator capable of generating sine, square, triangle, and sawtooth waveforms of up to 22 KHz. Calibration to an external reference signal is supported, guaranteeing the accuracy of measurements.

  • Low Power Potentiostats

    Bank Elektronik

    Potentiostat Wenking MP 04T, max. current 400 mA, max. voltage 25 V, output power 10 W, reference electrode input 1012 Ohms, slew rate 10 V/ µs, 1 control input, floating current output, buffered potential output, control range ± 10 V external, internal control voltage source ±2 V, rise time constant (closed loop, ohmic load) 1 µs typ., dimensions 165 x 105 x 165 mm (w x h x d), weight 1.4 kg

  • Portable Three-Phase Meter Site Analyzer

    RW-30X / RW-31X - Radian Research, Inc.

    RADIAN RW-30/31X Meter Site Analyzers deliver comprehensive three-phase field testing and site analysis utilizing the Radian Research RX Xytronic series reference standard as its measurement engine. The RW-30/31X provides for testing meters with integrated, precision, true three-phase voltage and current sources or using customer’s load. Choose the RW-30/31X NS (no source) model to test using customer’s load only.

  • RF COMPONENTS

    ETL Systems Ltd

    If space is an issue and you are looking for high quality RF Components, ETL's wide range is designed and manufactured at the ETL factory. Covering DC to 40GHz, these are at the heart of many of our 19" Rack Systems.A key feature of many of ETL components is the ability to pass or block a 10 MHz signal or DC voltage through the products, which can be used to power interconnecting components or pass a stable frequency reference to a LNB or BUC within the system.

  • DC to LVDT and DC to RVDT Converters

    Computer Conversions Corporation

    The SLVT Series are complete, low profile, continuously updating, single channel, Isolated Digital to LVDT Converters used to simulate the output of LVDT's (Linear velocity displacement transducers), RVDT's (Rotary...) and other phase/voltage sensitive AC devices. They provide a very precise linear AC voltage output proportionate to the magnitude of the input data, in or out of phase respective of the AC reference input as determined by the MSB of the input word (offset binary format).

  • PXI Millivolt Thermocouple Simulators

    Series 41-760 - Pickering Interfaces Ltd.

    This series of PXI Thermocouple Simulator Modules is available in a choice of 32, 24, 16 or 8 channelseach channel providing a low-voltage output across two connector pins capable of providing 20mV with 0.7V resolution, 50mV with 1.7V resolution and 100mV with 3.3V resolution, covering most thermocouple types. These thermocouple simulators use two wire outputs with a remote output reference sense to ensure the modules deliver accurate low-level voltages, even if the system has common mode voltages present. In addition, each simulation channel is also able to provide an open circuit setting to simulate faulty wiring connections to a sensor.

  • NI-6581B, 100 MHz, 54 Single-Ended-Channel, Kintex-7 FPGA-Support, Digital I/O Adapter Module for FlexRIO

    783887-01 - NI

    100 MHz, 54 Single-Ended-Channel, Kintex-7 FPGA-Support, Digital I/O Adapter Module for FlexRIO—The NI-6581B is a digital I/O adapter module that, when combined with a PXI FPGA Module for FlexRIO or the Controller for FlexRIO, creates a digital instrument for interfacing with 54 single-ended digital pins. A digital I/O adapter module for FlexRIO can be used to do real-time interfacing of standard protocols and implement customized protocols. The NI-6581B can operate sample digital waveforms at up to 100 MHz. It includes support for common transistor-to-transistor logic (TTL) voltage levels, or other voltage references can be sourced externally using a front panel connector.

  • Active Filter

    J2190A - PICOTEST Corp.

    The J2190A active filter presents a high impedance (approximately 150kOhms) minimizing the loading of the circuit being tested. The output impedance is 50 Ohms allowing low noise coaxial connections to all typical test equipment. The 0.1Hz-10Hz noise band is common for opamp measurements, voltage regulators and voltage references. Many application notes offer schematics of such a filter for test purposes. An engineer’s time is much too valuable to be spent building test equipment. We have created a 4th order high pass and 4th order low pass filter with an optimally flat response and 0dB gain. Additional filters can be cascaded for even sharper cutoff.

Get Help